This repository has been archived on 2023-11-20. You can view files and clone it, but cannot push or open issues or pull requests.
foam-extend4.1-coherent-io/applications/utilities/mesh/conversion/fluentMeshToFoam
Hrvoje Jasak 15a24604c7 Formatting
Conflicts:
	applications/solvers/basic/potentialDyMFoam/potentialDyMFoam.C
2015-04-07 16:34:36 +01:00
..
Make Moving to the new directory structure for dynamicMesh 2010-10-12 16:47:10 -04:00
cellShapeRecognition.H Renamed and cleaned foam-extend 2013-12-11 16:09:41 +00:00
create3DCellShape.C Renamed and cleaned foam-extend 2013-12-11 16:09:41 +00:00
extrudedQuadCellShape.C Renamed and cleaned foam-extend 2013-12-11 16:09:41 +00:00
extrudedTriangleCellShape.C Renamed and cleaned foam-extend 2013-12-11 16:09:41 +00:00
fluentMeshToFoam.L Formatting 2015-04-07 16:34:36 +01:00
README.txt Remove trailing whitespace systematically 2013-07-18 10:15:54 +02:00

Notes for fluentMeshToFoam with zone preservation
#################################################

1. New option added:
    - writeSets:
    Writes all Fluent boundaries faceSets preserving Fluent names
    Writes all Fluent regions to cellSets preserving Fluent names
    lines: 1375 - 1393 & 1673 - 1741
    sets are useful for post-processing using foamToVTK with the "-faceSet
    <name>" and "-cellSet <name>" options.

    - writeZones:
    Writes all regions to cellZones preserving Fluent names
    Writes all region internal face to faceZones preserving Fluent names
    lines: 1545 - 1667
    Zones are usefull for porous media and MRF calculations

2. Zone Access
    - Zones are simple lists of label lists that can be accessed from polyMesh
    with the cellZones(), faceZones() and pointZones() member functions

    - Example (Members from polyMesh.H and ZoneMesh.H):
    label thisCellZoneID = mesh.cellZones().findZoneID("thisZoneName");
    const labelList& thisCellZone = mesh.cellZones()[thisCellZoneID];

    - Zone integrity is preserved during mesh modification and decompomposition.

    - Once created via addZones, zones allow modification through non-const
    access

3. Fluent boundary types.
    - All internal and baffle elements are ignored during conversion

    - Boundary faces labelled as internal (i.e. interior, interface, internal,
    solid, fan, radiator, porous-jump) but that are in fact external boundaries