This test case serves to verify the time and under-relaxation consistent
|
||
|
formulation developed by CFD@FSB group (University of Zagreb). Pressure is
|
||
|
probed at four corners and in the centre of the lid driven cavity. Four
|
||
|
simulations are performed with four different time steps spanning four orders of
|
||
|
magnitude: 0.01, 0.001, 0.0001 and 0.00001 s. Tolerances for all equations are
|
||
|
very small, yielding extremely small (O(1e-11)) differences in converged
|
||
|
pressure field. If the differences are larger - it means that the converged
|
||
|
solution is not independent to time step size.
|
||
|
|
||
|
Author: Vuko Vukcevic, vuko.vukcevic@fsb.hr
|